MIL-PRF-87930B
Standard Test Method for Particulate Contaminant in Aviation Fuel
ASTM D2276
by Line Sampling (DoD Adopted)
Standard Practice for Using Significant Digits in Test Data to
ASTM E29
Determine Conformance with Specifications (DoD Adopted)
Standard Test Method for Iron in Trace Quantities Using the
ASTM E394
1,10-Phenanthroline Method
(Copies of these documents are available online at https://www.astm.org or ASTM International, 100 Barr
Harbor Drive, West Conshohocken PA 19428-2959).
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (EPA)
EPA 300.0
Determination of Inorganic Anions by Ion Chromatography.
(Copies of these documents are available online at https://water.epa.gov or call EPA New England
Customer Call Center at (888) 372-7341 for New England States or (617)918-111 for all others).
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a
conflict between the text of this document and the references cited herein (except for related specification
sheets), the text of this document takes precedence. Nothing in this document, however, supersedes
applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Chemical and physical properties. The chemical and physical properties of the propellant
mixture shall conform to those listed in Table I when tested according to the applicable test methods.
3.2 Limiting values. The following applies to all specified limits in this specification: For
purposes of determining conformance with these requirements, an observed value or a calculated value
shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification
limit according to the rounding-off method of ASTM Practice E29 Standard Practice for Using Significant
Digits in Test Data to Determine Conformance with Specifications.
3.3 Filter. A filter with a rating of at least 2 micrometer (µm) nominal and 10 µm absolute rating
shall be installed between the manufacturer's plant system and the container to be filled for delivery.
3.4 Qualitative. The propellant shall be colorless, homogeneous liquid when examined visually
by transmitted light.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business